AMS 2750F About calibration accuracy of sensor
Hello everybody, i have a questionabout calibration accuracy of sensor as below,According to AMS 2750F table 1,if the calibration accuracy of the type S control sensor is exceed the ±0.6℃ or±0.1%,
shall we scrap the sensor or continue to use the sensor with correction factors?
Hope your answer! You shall use the sensor with correction factor. see table1 note(9). In my opinion, we have to scrap these sensors becuase they can't mee the requirements.
For table 1 Note 9
I think it is only suitable for sensors type not listed in Table 1 and used above 1316℃ then we can follow up the rules of Note 9. See table1 note(9).....